| Gasket Type | Core Material System | Key Applications | Differentiators |
Conductive Foam Gaskets |
Open-cell PU foam + Ni/Cu or Ag coating (0.5–3mm) | Consumer electronics, industrial controllers, IoT gateways | Ultra-low compression set (<10%), Y-axis continuous wrapping; ideal for high-cycle assembly |
Fabric-Over-Foam (FOF) Gaskets |
0.016mm black conductive fabric (Ni/Cu) + PU foam core | Smartphone/iPad display frames, EV sensor housings, wearables | Aesthetic black finish, surface resistance <0.1Ω, non-corrosive to aluminum alloys |
Conductive Elastomer Gaskets |
Solid silicone rubber + Ag-Al/Ni-C particles (Shore A 40–70) | Automotive ECUs, medical imaging devices, aerospace avionics | Stable to 150°C, IP67 sealing, passes Telcordia GR-468-CORE, low outgassing (ASTM E595) |
Conductive Elastomer Gaskets |
High-purity silicone + AlN/ZnO fillers (≥5 W/m·K, 0.5–3.0mm) | AI server GPU brackets, 5G base station PA modules, power inverters | UL94 V-0, RoHS, reworkable, no pump-out; optimized for EMI-shielded thermal paths |
Custom EMI Shielding Gaskets |
Customer-specific: Silicone/EPDM + embedded Ag/Ni wire mesh or conductive fabric; molded/cut to exact housing geometry | 5G RRH enclosures, radar modules, battery management systems (BMS), satellite comms | Full CAD-to-part workflow: 3D scan → FEA simulation → tooling → 7-day prototyping; achieves >60 dB shielding @1GHz + thermal path integration |
When selecting EMI
| Stress | Risk | Our Solution |
| Thermal Cycling (–40°C ↔ 150°C) | Compression set → loss of SE | Silicone elastomers with <15% set after 1,000h |
| Humidity/Salt Fog | Corrosion of mating surface | Non-sulfur formulations; pass ASTM B117 |
| Vibration | Gasket displacement | Adhesive-backed options or mechanical retention |
| Requirement | Test Method | Our Capability |
| Shielding Effectiveness | ASTM D4935 | 60–100 dB (30 MHz – 10 GHz) |
| Outgassing | ASTM E595 | TML <0.1% (critical for optics) |
| Corrosivity | Telcordia GR-468 | Pass (no sulfur/chlorine) |
| Thermal Aging | ISO 188 / IEC 60068-2-2 | Stable SE after 1,000h @ 150°C |
| Biocompatibility | ISO 10993 | Available for medical-grade gaskets |